Please use this identifier to cite or link to this item: http://hdl.handle.net/123456789/1043
Title: Detection of cytostatic drugs in municipal waste water and their transfer to surface water
Authors: Galaon, Toma
Petre, Jana
Iancu, Vasile
Cruceru, Liliana
Niculescu, Marcela
Chiriac, Florentina Laura
Puiu, Diana
Mihalache, Madalina
Keywords: Cytostatic drugs;LC-ESI-MS/MS;Metabolites;Municipal wastewater
Issue Date: 2017
Publisher: National Research and Development Institute for Industrial Ecology, INCD-ECOIND
Abstract: 
A new sensitive and selective LC-MS/MS method with positive electrospray ionization was developed to detect seven cytostatic drugs and one metabolite from municipal wastewater. The method separates the target analytes in only 16 minutes using a Hypersil Gold column (100 x 2.1 mm, 3.0 µm) kept at 20°C and a mobile
phase made of aq. 0.2% HCOOH and ACN in the ratio 92/8 (v/v). A low mobile phase flow of 0.2 mL/min was used to increase MS ionization yield and hence method sensitivity. A complex two steps (10%/minute) and two plateau gradient elution program was applied for 12 minutes to achieve analyte separation from matrix and
each other with highly efficient peaks. Collision energy, fragmentor and capillary voltages were optimized to increase MS sensitivity. Optimization of LC-MS parameters generated low instrumental LOQs situated in the range 0.1 ÷ 1.0 ng/mL. MS detector response was linear between 1 and 100 ng/mL with R2 coefficients >
0.997 for all eight target analytes. SPE using Oasis HLB cartridges was employed to concentrate target analytes from water samples with MeOH as elution solvent. Intraday and inter-day precision (RSD %) was situated between 5.4 ÷ 7.2% and 7.3 ÷ 10.8%, respectively. Cytostatics recovery after SPE was good due to internal standard correction with values between 70 ÷ 134%. Overall method LOQs were situated
between 0.6 and 5.6 ng/L. The method was tested on four waste water samples from a WWTP plant in Bucharest, but none of the targeted cytostatic drugs were found above detection limit.
Description: 
International Symposium "The Environment and the Industry", SIMI 2017
URI: http://hdl.handle.net/123456789/1043
10.21698/simi.2017.0029
ISSN: L : 1843-5831 (on-line): 2457-8371
Appears in Collections:SIMI 2017

Files in This Item:
File Description SizeFormat
29.pdf576.1 kBAdobe PDFView/Open
Detection of WOS Record.pdf186.68 kBAdobe PDF    Request a copy
Show full item record

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.