Please use this identifier to cite or link to this item: http://hdl.handle.net/123456789/1136
DC FieldValueLanguage
dc.contributor.authorVasile, Gabriela-
dc.contributor.authorArnold, Georgiana Luiza-
dc.contributor.authorBuica, George Octavian-
dc.contributor.authorDiacu, Elena-
dc.contributor.authorUngureanu, Eleonora-Mihaela-
dc.contributor.authorDinu, Cristina-
dc.date.accessioned2018-02-06T08:50:16Z-
dc.date.available2018-02-06T08:50:16Z-
dc.date.issued2018-
dc.identifier.issn0034-7752-
dc.identifier.urihttp://hdl.handle.net/123456789/1136-
dc.descriptionRevista de Chimie (Bucuresti), 2018, 69(1), p. 21-26en_US
dc.description.abstractThis study develops a new electrochemical method for quantification of Pb in soft water using stripping voltammetry with a glassy carbon electrode modified with the functionalized azulene: (2E)-2-(azulen-1- ylmethylidene) hydrazine carbothioamide (L)as a complexing polymer film. The optimized steps of the proposed method consisted in experimental establishing of four parameters, namely: reduction time; reduction potential; complexation time; pH in acetate buffer and phosphate buffer. The modified electrodes were prepared in L solutions (1mM) in acetonitrile (CH3CN) containing tetra n-butyl ammonium perchlorate (0.1 M TBAP) as supporting electrolyte. The electrochemical method includes four main operations: 1) polymeric film formation by controlled potential electrolysis (CPE) at 1.7V using a charge of 1 mC; 2) film conditioning in 0.1 M buffer acetate solution using cyclic voltammetry; 3) 25 min complexation time in a standard solution prepared from lead nitrate (II) using as matrix ultrapure water or a real sample; 4) stripping by differential pulse voltammetry method (DPV) in acetate buffer at pH 4.0, after 120 s reduction time at a reduction potential of -1.0 V. Determination time for a single standard solution or real sample was around 45 min. Evaluation of the method performance parameters (linearity, working range, detection limit, quantification limit, repeatability, and recovery) was done. It confirms that the proposed method is suitable to detect and quantify lead content over 1.2 µg/L in soft water samples.en_US
dc.description.sponsorshipThis work was supported by a grant of the Romanian National Authority for Scientific Research - Program PN-IIPT-PCCA-2013-4-2151, financing contract no. 236/2014, SEMEMAen_US
dc.language.isoen_USen_US
dc.publisherSYSCOM 18 SRLen_US
dc.subjectPoly[(2E)-2-(azulen-1-ylmethylidene) hydrazine carbothioamide]en_US
dc.subjectLeaden_US
dc.subjectStripping voltammetryen_US
dc.subjectPolymeric filmen_US
dc.subjectSoft wateren_US
dc.titleStripping voltammetry on a new modified Glassy Carbon Electrode for lead content determination in soft wateren_US
dc.typeArticleen_US
item.fulltextWith Fulltext-
item.cerifentitytypePublications-
item.grantfulltextopen-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypeArticle-
item.languageiso639-1en_US-
crisitem.author.deptNational Research and Development Institute for Industrial Ecology, ECOIND-
crisitem.author.deptUniversity Politehnica of Bucharest, Romania-
crisitem.author.deptNational Research and Development Institute for Industrial Ecology, ECOIND-
crisitem.author.deptNational Research and Development Institute for Industrial Ecology, ECOIND-
crisitem.author.orcid0000-0001-7876-4420-
crisitem.author.orcid0000-0002-7974 -9318-
Appears in Collections:Articles
Files in This Item:
File Description SizeFormat
5 VASILE GABRIELA 1 18.pdf1.1 MBAdobe PDFView/Open
Show simple item record

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.