Please use this identifier to cite or link to this item: http://hdl.handle.net/123456789/1526
DC FieldValueLanguage
dc.contributor.authorBucur, Elena-
dc.contributor.authorDanet, Andrei Florin-
dc.date.accessioned2019-10-22T10:42:48Z-
dc.date.available2019-10-22T10:42:48Z-
dc.date.issued2019-02-
dc.identifier.issn1582-9596-
dc.identifier.urihttp://hdl.handle.net/123456789/1526-
dc.descriptionEnvironmental Engineering and Management Journal, vol. 18, nr. 2, pag. 425-432, 2019en_US
dc.description.abstractThis paper presents the results of a case study conducted between 2.04 and 24.04.2013 in order to establish the most relevant indicators that characterize the influence of outdoor air pollution, with particulate matter having a nominal diameter less than 2.5μm (PM2.5), on the quality of indoor air from a new building. The tests consisted in simultaneous determination of the daily average PM2.5 concentrations at four indoor sites and at one outside, nearby the building. The average PM2.5 concentration was 38.41±7.4μg/m3, but only 70% of the outdoor performed tests were above the daily limit of 35μg/m3, set by the U.S. Environmental Protection Agency. The indoor air pollution with PM2.5 was lower than outdoor with an average concentration of 21.78 ±6.22 μg/m3. Both Pearson’s statistical correlation analysis and linear regression analysis showed a good direct correlation between indoor and outdoor PM2.5 concentrations, the proper insulation of the building and the absence of major indoor sources of PM2.5 particles. The results of this study demonstrated that for a new building the indoor/outdoor (I/O) ratio and infiltration factor (Fin) could give a correct estimation of the outdoor air pollution influence on the indoor air quality. Further information could be provided by statistical correlation and linear regression analysis; the value of the intercept could be a good indicator of the presence of indoor sources.en_US
dc.language.isoen_USen_US
dc.publisherGheorghe Asachi Technical University of Iasien_US
dc.subjectI/O Ratioen_US
dc.subjectIndoor airen_US
dc.subjectInfiltration factoren_US
dc.subjectPenetration factoren_US
dc.subjectPM2.5en_US
dc.titleIndoor/Outdoor Correlations Regarding Indoor Air Pollution With Particulate Matteren_US
dc.typeArticleen_US
item.grantfulltextreserved-
item.languageiso639-1en_US-
item.openairetypeArticle-
item.fulltextWith Fulltext-
item.cerifentitytypePublications-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
crisitem.author.deptNational Research and Development Institute for Industrial Ecology, INCD-ECOIND-
crisitem.author.deptUniversity of Bucharest, Romania-
crisitem.author.orcid0000-0002-1414-5126-
Appears in Collections:Articles
Show simple item record

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.