Please use this identifier to cite or link to this item:
http://hdl.handle.net/123456789/1674
Title: | New ion-chromatography method for detection of chlorite, chlorate, and bromate in drinking water | Authors: | Paun, Iuliana Iancu, Vasile Chiriac, Florentina Laura Vasilache, Nicoleta Pirvu, Florinela Niculescu, Marcela Galaon, Toma |
Affiliations: | National Research and Development Institute for Industrial Ecology, ECOIND | Keywords: | Chlorite;Chlorate;Bromate;Ion chromatography;Drinking water | Issue Date: | Oct-2020 | Publisher: | National Research and Development Institute for Industrial Ecology, INCD-ECOIND | Abstract: | A direct ion chromatographic method for determination of chlorite, chlorate and bromate in the presence of fluoride, chloride, nitrate, nitrite and bromide in treated drinking waters was described. Separation of target analytes was achieved using an AS19-HC analytical column (250 mm x 4 mm), AG 19-HC guard column (50 mm x 4 mm) and KOH 25 mmol/L as mobile phase. Inorganic analytes were eluted using a flow rate of 1 mL/min. Column temperature was set up and maintained at 300C. The analyte ions were quantified using a suppressed conductivity detector. |
Description: | Romanian Journal of Ecology & Environmental Chemistry, vol. 2, no. 2, 2020, p. 49-55 |
URI: | http://hdl.handle.net/123456789/1674 |
Appears in Collections: | RJEEC, Volume 2, no. 2, 2020 |
Show full item record