Please use this identifier to cite or link to this item: http://hdl.handle.net/123456789/787
Title: Achiral–chiral LC/LC–FLD coupling for determination of carvedilol in plasma samples for bioequivalence purposes
Authors: Medvedovici, Andrei
Albu, Florin
Georgita, Cristina
Sora, Daniela Iuliana
Galaon, Toma
Udrescu, Stefan
David, Victor
Keywords: Carvedilol;Racemate;Enantiomers;Bidimensional LC;Achiral and chiral RPLC separation mechanisms;Cellulose tris(3,5-dimethyl-phenylcarbamate);Simultaneous monitoring;Fluorescence detection;Bioequivalence study;Solid oral dosage forms;Pharmacokinetic parameters
Issue Date: 2007
Publisher: Elsevier
Abstract: 
Bioequivalence data for two pharmaceutical formulations (solid oral dosage forms) containing carvedilol is presented for both racemic and enantiomers of the active substance. This was achieved by on-line coupling of two liquid chromatographic separations followed by fluorescence detection. The first LC dimension was used for a fast separation of racemic carvedilol from propranolol (IS) and the endogenous matrix, by means
of a reversed phase mechanism. The peak of racemic carvedilol was on-line transferred to the second enantioselective LC dimension, based on a reversed phase separation on cellulose tris(3,5-dimethyl-phenylcarbamate) stationary phase. Both stages were monitored over a single run by means of a fluorescence detector operated at an excitation wavelength of 285 nm and an emission wavelength of 355 nm. Automated shortcutting of the racemic carvedilol peak to the chiral column and simultaneous detection over the two LC dimensions have been obtained by using an experimental set-up based on two six-port rotative switching valves. Linearity was demonstrated on the interval 2–150 ng/mL for racemic carvedilol and on 1–75 ng/mL intervals for enantiomers. LLOQ fits between 0.7 and 1.4 ng/mL. Recoveries of the target compounds are 87±4 and 81±4% for the IS. Precision ranged from 0.6 to 2.5% and the mean accuracy obtained on quality control samples (measured as % bias) over the whole study falls between −0.8 and 6.3%.
Description: 
Journal of Chromatography B Volume 850
URI: http://hdl.handle.net/123456789/787
ISSN: 1570-0232
Appears in Collections:Articles

Files in This Item:
File Description SizeFormat Existing users please
A ISI JCB CARVED 2007.pdf284.7 kBAdobe PDF    Request a copy
Show full item record

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.