Conference Papers
Permanent URI for this collection
introductoryText(language){return this.firstMetadataValue("dc.description",{language})}
News
sidebarText(language){return this.firstMetadataValue("dc.description.tableofcontents",{language})}
Browse
Browsing Conference Papers by Author "Batrinescu, Gheorghe"
Now showing 1 - 2 of 2
Results Per Page
Sort Options
Publication Degradation of triclosan from aqueous systems using a photocatalytic membrane reactor
(SGEM WORLD SCIENCE , 2015) ;Constantin, Lucian Alexandru ;Nitoi, Ines ;Batrinescu, Gheorghe ;Cristea, IonutNechifor, GheorgheNowadays there is an increased concern regarding the triclosan (TCS) – 5 chloro – 2 – (2,4 – dichlorophenoxy) phenol persistence, toxicity and potential negative impact upon the environment. TCS is used on a large scale for personal care products fabrication and therefore is present within the wastewater treatment plants discharged effluents and sludge. Due to its persistence and toxicity, UV/TiO2 photocatalysis coupled with membrane processes for catalyst recovery is representing a promising treatment method for aqueous systems with TCS content. The degradation of triclosan using a photocatalytic membrane reactor utilizing photocatalyst in suspension was studied. The proposed treatment sequence consists of two main steps. First one is heterogeneous UV/TiO2 photocatalysis followed by the second - photocatalyst separation using a polymeric membrane and its reuse within the next treatment cycle together with fresh photocatalyst addition in order to assure optimum photocatalyst dose. UV/TiO2 photocatalysis was performed in the following working conditions: pH = 6.5, catalyst optimum dose [TiO2] = 200 mg/L, time t = 90 minutes. Photocatalyst separation was realized using an ultrafiltration polymeric membrane (12% polysulfone) at a working pressure of 2 bars until a concentration ratio of ½ was achieved. The membrane played a double role both in photocatalyst separation and as barrier for remanent pollutant and degradation by-products molecules. It was found that proposed treatment sequence is efficient for five cycles with no need of membrane cleaning / replacement and with TCS degradation efficiency varying from 99.72% (1st cycle) to 93.52% (5th cycle). The photocatalyst consumption was reduced with 52% in comparison with classic UV/TiO2 photocatalysis processes.61 1 Publication Process for obtaining a product with a high concentration of squalene
(Technical University Gheorghe Asachi of Iasi , 2018-06); ; ; 2 33