Repository logoRepository logoEcolib
Institutional
repository
  • Communities & Collections
  • Browse
AAA
  • Log In
    New user? Click here to register.Have you forgotten your password?
  1. Home
  2. ECOLOGY AND POLLUTION CONTROL
  3. Articles
  4. Liquid Chromatography Tandem Mass Spectrometry Method for Ultra-Trace Analysis of Organic UV Filters in Environmental Water Samples
 
  • Details
Options

Liquid Chromatography Tandem Mass Spectrometry Method for Ultra-Trace Analysis of Organic UV Filters in Environmental Water Samples

Date issued
2020-01
Author(s)
Chiriac, Florentina Laura  
National Research and Development Institute for Industrial Ecology, ECOIND  
Paun, Iuliana  
National Research and Development Institute for Industrial Ecology, ECOIND  
Pirvu, Florinela  
National Research and Development Institute for Industrial Ecology, ECOIND  
Pascu, Luoana Florentina  
National Research and Development Institute for Industrial Ecology, ECOIND  
Niculescu, Marcela  
National Research and Development Institute for Industrial Ecology, ECOIND  
Galaon, Toma  
National Research and Development Institute for Industrial Ecology, ECOIND  
DOI
10.37358/RC.20.1.7818
Abstract
A liquid chromatography-tandem mass spectrometry (SPE-LC-MS/MS) method was developed and validated for the simultaneous determination of six organic compounds (2-hydroxy benzophenone, 4- hydroxy benzophenone, 2,2’,4,4’-tetrahydroxy benzophenone, 2,4-dyhydroxy benzophenone, 4,4’- dyhydroxy benzophenone, 2,2’-dyhydroxy-4-methoxy-benzophenone) used as UV filters in personal care products used to protect against UV radiation. The major concern about this type of pollutants is due to their persistence and bioaccumulation potential in the environment and aquatic organisms and for their endocrine disruptor properties. Solid phase extraction was used for sample preparation, followed by liquid chromatography tandem mass spectrometry analysis. Benzophenone derivatives were analyzed on a Phenomenex Luna C18 column (150 x 2.0 mm, 3.0 µm) with the mobile phase run in gradient mode with a mixture of aqueous 0.1% formic acid and acetonitrile as the mobile phase components (at a flow rate of 0.2 mL/min). MS detector response was linear, on the tested concentration domain from 1 to 100 μg/L with correlation coefficient R2 > 0.998. The recoveries of benzophenone derivatives after solid phase extraction procedure from surface water was found to be >81% for surface water and higher than 79% for wastewater matrix. The standard deviation values for intra-day precision were situated between 7.67% and 9.88% for lower concentration and 7.27% and 8.86% for higher concentration respectively. The limits of quantitation were calculated for both environmental water matrices (1.6-4.1 ng/L for surface water and 3.3-8.2 ng/L for wastewater). This method can be applied for benzophenone derivatives detection in real environmental samples.
Subjects

Organic UV filters

Benzophenone derivati...

Solid phase extractio...

LC-MS/MS

Method

Files
Loading...
Thumbnail Image
Name

15 CHIRIAC F L 1 20.pdf

Description
Article
Size

644.62 KB

Format

Adobe PDF

Checksum

(MD5):3eeb3d68b18e21c08e91d8a271561223

ECOIND logoECOIND logo
ECOLIB logoECOLIB logo
ROAR
ECOLIB logoECOLIB logo
Copyright 2025 ECOIND | End User Agreement | Send Feedback | Cookie settings | Privacy policy
DSpace Software Provided by PCG Academia