Repository logoRepository logoEcolib
Institutional
repository
  • Communities & Collections
  • Browse
AAA
  • Log In
    New user? Click here to register.Have you forgotten your password?
  1. Home
  2. ECOLOGY AND POLLUTION CONTROL
  3. Articles
  4. Graphene oxide electroreduced onto boron-doped diamond and electrodecorated with silver (Ag/GO/BDD) electrode for tetracycline detection in aqueous solution
 
  • Details
Options

Graphene oxide electroreduced onto boron-doped diamond and electrodecorated with silver (Ag/GO/BDD) electrode for tetracycline detection in aqueous solution

Date issued
2021-06
Author(s)
Negrea, Sorina Claudia  
National Research and Development Institute for Industrial Ecology, ECOIND  
Diaconu, Lidia Ani  
National Research and Development Institute for Industrial Ecology, ECOIND  
Nicorescu, Valeria  
National Research and Development Institute for Industrial Ecology, ECOIND  
Motoc, Sorina  
“Coriolan Dragulescu” Institute of Chemistry Timisoara of Romanian Academy  
Orha, Corina  
National Research and Development Institute in Electrochemistry and Condensed Matter  
Manea, Florica  
Politehnica University of Timisoara  
DOI
10.3390/nano11061566
Abstract
A new electrochemical sensor designed by modifying the commercial boron-doped diamond (BDD) electrode with graphene oxide (GO) reduced electrochemically and further electrodecorated with silver (Ag), named the Ag/GO/BDD electrode, was selected among a series of the BDD, GO electroreduced onto BDD (GO/BDD) and silver electrodeposited onto BDD (Ag/BDD) electrodes for the detection of tetracycline (TC) in aqueous solution. The best results regarding the sensitivity of 46.6 µA · µM −1 ·cm −2 and the lowest limit of detection of 5 nM was achieved using square-wave voltammetry (SWV) operated at the step potential of 5 mV, modulation amplitude of 200 mV, and the frequency of 10 Hz in alkaline medium. The application of the alkaline supporting electrolyte-based procedure is limited for water monitoring due to the presence of chloride that interferes with TC detection; however, it can be applied for the quantitative determination of pharmaceutical formulations. 0.1
M Na2SO4 supporting electrolyte eliminated chloride interference and can be used for the application
of Ag/GO/BDD in practical detection of TC in water.
Subjects

Silver electrocatalys...

Tetracycline

Electrochemical detec...

Silver-graphene oxide...

Files
Loading...
Thumbnail Image
Name

Graphene Oxide Electroreduced onto Boron Doped Diamond.pdf

Description
Article
Size

5.58 MB

Format

Adobe PDF

Checksum

(MD5):a3499811c5ea4755bf99f751ebe4312e

ECOIND logoECOIND logo
ECOLIB logoECOLIB logo
ROAR
ECOLIB logoECOLIB logo
Copyright 2025 ECOIND | End User Agreement | Send Feedback | Cookie settings | Privacy policy
DSpace Software Provided by PCG Academia