Publication:

Determination of benzalkonium chlorides from wastewater using HPLC-DAD method

cris.virtual.departmentNational Research and Development Institute for Industrial Ecology, ECOIND
cris.virtual.departmentUniversity Politehnica of Bucharest, Romania
cris.virtual.orcid0000-0002-5026-0551en_US
cris.virtual.orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtualsource.departmentea03e3e2-5cb2-442f-969e-4066a19d2c34
cris.virtualsource.department57251562-2481-47f4-9ed7-3cd8f6b60383
cris.virtualsource.orcidea03e3e2-5cb2-442f-969e-4066a19d2c34
cris.virtualsource.orcid57251562-2481-47f4-9ed7-3cd8f6b60383
dc.contributor.authorPaun, Iulianaen_US
dc.contributor.authorCovaliu, Cristina Ileanaen_US
dc.date.accessioned2023-10-21T14:54:06Z
dc.date.available2023-10-21T14:54:06Z
dc.date.issued2023
dc.descriptionU.P.B. Sci. Bull., Series B, vol. 85, nr. 2, 2023, pag. 97-104en_US
dc.description.abstractThis article presents the development and validation of a new high-performance liquid chromatography (HPLC) method coupled with a diode array detector for the simultaneous analysis of benzalkonium chlorides (benzyl dimethyl dodecyl ammonium chloride, C12-BZCL, benzyl dimethyl tetradecyl ammonium chloride, C14-BZCL and benzyl dimethyl hexadecyl ammonium chloride, C16-BZCL) from wastewater samples. The chromatographic analysis was performed on an Acclaim Surfactant Plus (150 x 3.0 mm, 3 μm d.p.) column acquired from Thermo Scientific, kept at 30°C. All experiments were performed in isocratic elution conditions at a flow-rate of 0.5 mL/min. Mobile phase composition was a mixture of acetonitrile (A) and 0.2 M ammonium acetate solution (50:50, v/v). UV –VIS detection was λ = 262 nm for the three BZCL. The limits of detection (LODs) were obtained 15 µg/L (C12- BZCL), 19 µg/L (C14- BZCL) and 25 µg/L (C16- BZCL). The calibration curves were linear between 1 mg/L - 100 mg/L, with R2 values above 0.999 for all BZCL. Solid phase extraction (SPE) using polymeric (Strata X) cartridges has been applied to extract and concentrate the target analytes from the wastewater. BZCL recoveries after the SPE procedure were situated between 86.0÷94.6%. Intra-day and inter-day precision (RSD%) were between 1.4 ÷ 2.3% and 6.2 ÷ 6.7%, respectively. Limits of quantification (LOQs) was 4.5 µg/L (C12-BZCL), 5.6 µg/L (C14-BZCL) and 7.6 µg/L (C16- BZCL).en_US
dc.identifier.urihttp://hdl.handle.net/123456789/1981
dc.language.isoenen_US
dc.publisherUniversity Politehnica Bucharesten_US
dc.relation.issn1454-2331
dc.relation.journalU.P.B. Sci. Bull., Series B
dc.subjectbenzalkonium chlorideen_US
dc.subjectHPLC/DADen_US
dc.subjectSPEen_US
dc.subjectSurfactanten_US
dc.subjectWastewateren_US
dc.title

Determination of benzalkonium chlorides from wastewater using HPLC-DAD method

en_US
dc.typejournal articleen_US
dspace.entity.typePublication
oairecerif.author.affiliationNational Research and Development Institute for Industrial Ecology, ECOINDen_US
oairecerif.author.affiliationUniversity Politehnica of Bucharest, Romaniaen_US
Files

Original bundle

Name:
Articol Iuliana Paun UPB.pdf
Size:
305.18 KB
Format:
Adobe Portable Document Format
Description:
Article

License bundle

Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description:
Publication available in collections: