Repository logoRepository logoEcolib
Institutional
repository
  • Communities & Collections
  • Browse
AAA
  • Log In
    New user? Click here to register.Have you forgotten your password?
  1. Home
  2. ROMANIAN JOURNAL OF ECOLOGY & ENVIRONMENTAL CHEMISTRY
  3. RJEEC, Volume 6, no. 2, 2024
  4. Indirect electrochemical detection of perfluoro decanoic acid from water
 
  • Details
Options

Indirect electrochemical detection of perfluoro decanoic acid from water

Journal
Romanian Journal of Ecology & Environmental Chemistry
ISSN
2668-8530
Date issued
2024-12-23
Author(s)
Negrea, Sorina Claudia  
National Research and Development Institute for Industrial Ecology, ECOIND  
Diaconu, Lidia Ani  
National Research and Development Institute for Industrial Ecology, ECOIND  
Trif, Elena
Politehnica University of Timisoara  
Pacala, Adina  
National Research and Development Institute for Industrial Ecology, ECOIND  
Neidoni, Dorian Gabriel  
National Research and Development Institute for Industrial Ecology, ECOIND  
Pascu, Luoana Florentina  
National Research and Development Institute for Industrial Ecology, ECOIND  
Motoc, Sorina  
“Coriolan Dragulescu” Institute of Chemistry Timisoara of Romanian Academy  
Baciu, Anamaria  
Politehnica University of Timisoara  
Manea, Florica  
Politehnica University of Timisoara  
DOI
10.21698/rjeec.2024.212
Abstract
<jats:p>Electrochemical detection of perfluoro decanoic acid (PFDA) has gained significant interest due to the its environmental persistence and potential health risks. This study focuses on the development and utilization of a molecular imprinted polymer (MIP) sensor for the selective and sensitive detection of PFDA in aqueous samples. Commercial boron-doped diamond (BDD) electrode was modified with MIP by electro polymerization in 2:1 (v/v) mixture of 0.1 M sodium acetate buffer solution (pH = 5.8) and methanol containing 10 mM o-phenylenediamine (o-PD) and 1 mM PFDA concentration. The electro polymerization process was carried out using cyclic voltammetry (CV) by scanning 25 cyclic voltammograms in a potential range of 0.00 →1.00 V/SCE with a scan rate of 0.05 V·s-1. The electrochemical performance of the MIP-BDD sensor using cyclic voltammetry (CV), differential pulse voltammetry (DPV) and square wave voltammetry (SWV) was assessed. Considering both voltametric detections based on oxygen reduction reaction (ORR) and the lack of electrochemical activity of PFDA, investigation of its signal in the presence of increased PFDA concentrations is exploited for development of indirect detection method. Linear dependence between signal decrease vs. increasing PFDA concentrations allowed determining sensitivity and the lowest limit of detection of 0.160 nM (0.08 µg·dm-3) PFDA. The integration of MIP technology with electrochemical sensors offers a robust platform for environmental monitoring of PFDA, combining high selectivity, sensitivity and rapid response time. This method holds promise for advancing detection techniques for persistent organic pollutants in environmental and public health contexts.</jats:p>
Subjects

electro polymerizatio...

electrochemical detec...

molecular imprinted p...

o-phenylenediamine

perfluoro decanoic ac...

Files
Loading...
Thumbnail Image
Name

Articol 12 Full.pdf

Size

346.74 KB

Format

Adobe PDF

Checksum

(MD5):1e3d4323f7325139b470dd5394e583d0

ECOIND logoECOIND logo
ECOLIB logoECOLIB logo
ROAR
ECOLIB logoECOLIB logo
Copyright 2025 ECOIND | End User Agreement | Send Feedback | Cookie settings | Privacy policy