Options
In-house validation of a new method for determining high concentrations of NO2 in the exhaust gases associated stationary sources according to Order 462/1993
Date issued
2007
Author(s)
Abstract
It was developed a method of analysis for determining NO2 performance of residual gaseous effluents. Complex validation methodology "in-house" meet current standards applied by confirming identification and selectivity / specificity, fix the limit of detection, limit of quantification of the working range, linearity, robustness and recovery. It is applicable to the determination of concentrations of NO2 related residual gaseous effluents into the atmosphere stationary source emission values for NO2 concentration exceeding 50 mg / ml. Nitrogen oxides except nitrous oxide (N2O), are oxidized to nitrate and measured by UV absorbance molecular. The requirements SR EN ISO / IEC 17025: 2005 on summer use testing methods developed in its own laboratories, but only after validation. It was performed calculating the uncertainty of measurement method for determining
nitrogen dioxide and was drafted by the validated protocol documentation.
nitrogen dioxide and was drafted by the validated protocol documentation.
Files
Loading...
Name
Project_18_EP.pdf
Size
134.78 KB
Format
Adobe PDF
Checksum
(MD5):b8d453f30e78ac3dd1306c04c4373805