  4. Indoor/Outdoor Correlations Regarding Indoor Air Pollution With Particulate Matter
 
  • Details
Options

Indoor/Outdoor Correlations Regarding Indoor Air Pollution With Particulate Matter

Date issued
2019-02
Author(s)
Bucur, Elena  
National Research and Development Institute for Industrial Ecology, ECOIND  
Danet, Andrei Florin  
University of Bucharest, Romania  
DOI
10.30638/eemj.2019.040
Abstract
This paper presents the results of a case study conducted between 2.04 and 24.04.2013 in order to establish the most relevant indicators that characterize the influence of outdoor air pollution, with particulate matter having a nominal diameter less than 2.5μm (PM2.5), on the quality of indoor air from a new building. The tests consisted in simultaneous determination of the daily average PM2.5 concentrations at four indoor sites and at one outside, nearby the building. The average PM2.5 concentration was 38.41±7.4μg/m3, but only 70% of the outdoor performed tests were above the daily limit of 35μg/m3, set by the U.S. Environmental Protection Agency. The indoor air pollution with PM2.5 was lower than outdoor with an average concentration of 21.78 ±6.22 μg/m3. Both Pearson’s statistical correlation analysis and linear regression analysis showed a good direct correlation between indoor and outdoor PM2.5 concentrations, the proper insulation of the building and the absence of major indoor sources of PM2.5 particles. The results of this study demonstrated that for a new building the indoor/outdoor (I/O) ratio and infiltration factor (Fin) could give a correct estimation of the outdoor air pollution influence on the indoor air quality. Further information could be provided by statistical correlation and linear regression analysis; the value of the intercept could be a good indicator of the presence of indoor sources.
Subjects

I/O Ratio

Indoor air

Infiltration factor

Penetration factor

PM2.5

Files
No Thumbnail Available
Name

E. Bucur, A. Danet, 2019, IndoorOutdoor correlations regarding indoor air pollution with particulate matter, EEMJ.pdf

Size

1.44 MB

Format

Adobe PDF

Checksum

(MD5):5b1d6af8df46b1722e95f94ff6ba60da

ECOIND logoECOIND logo
ECOLIB logoECOLIB logo
ROAR
ECOLIB logoECOLIB logo
Copyright 2025 ECOIND | End User Agreement | Send Feedback | Cookie settings | Privacy policy
DSpace Software Provided by PCG Academia