Achiral–chiral LC/LC–FLD coupling for determination of carvedilol in plasma samples for bioequivalence purposes

Date issued
2007
Author(s)
Medvedovici, Andrei
Albu, Florin
Georgita, Cristina
Sora, Daniela Iuliana
Galaon, Toma
Udrescu, Stefan
David, Victor
Abstract
Bioequivalence data for two pharmaceutical formulations (solid oral dosage forms) containing carvedilol is presented for both racemic and enantiomers of the active substance. This was achieved by on-line coupling of two liquid chromatographic separations followed by fluorescence detection. The first LC dimension was used for a fast separation of racemic carvedilol from propranolol (IS) and the endogenous matrix, by means
of a reversed phase mechanism. The peak of racemic carvedilol was on-line transferred to the second enantioselective LC dimension, based on a reversed phase separation on cellulose tris(3,5-dimethyl-phenylcarbamate) stationary phase. Both stages were monitored over a single run by means of a fluorescence detector operated at an excitation wavelength of 285 nm and an emission wavelength of 355 nm. Automated shortcutting of the racemic carvedilol peak to the chiral column and simultaneous detection over the two LC dimensions have been obtained by using an experimental set-up based on two six-port rotative switching valves. Linearity was demonstrated on the interval 2–150 ng/mL for racemic carvedilol and on 1–75 ng/mL intervals for enantiomers. LLOQ fits between 0.7 and 1.4 ng/mL. Recoveries of the target compounds are 87±4 and 81±4% for the IS. Precision ranged from 0.6 to 2.5% and the mean accuracy obtained on quality control samples (measured as % bias) over the whole study falls between −0.8 and 6.3%.
Subjects

Carvedilol

Racemate

Enantiomers

Bidimensional LC

Achiral and chiral RP...

Cellulose tris(3,5-di...

Simultaneous monitori...

Fluorescence detectio...

Bioequivalence study

Solid oral dosage for...

Pharmacokinetic param...

Files
No Thumbnail Available
Name

A ISI JCB CARVED 2007.pdf

Size

284.7 KB

Format

Adobe PDF

Checksum

(MD5):681c6c6f5ee7d39521268b58e3808986

ECOIND logoECOIND logo
ECOLIB logoECOLIB logo
ROAR
ECOLIB logoECOLIB logo
Copyright 2025 ECOIND | End User Agreement | Send Feedback | Cookie settings | Privacy policy
DSpace Software Provided by PCG Academia