Repository logoRepository logoEcolib
Institutional
repository
  • Communities & Collections
  • Browse
AAA
  • Log In
    New user? Click here to register.Have you forgotten your password?
  1. Home
  2. ECOLOGY AND POLLUTION CONTROL
  3. Articles
  4. Fast and sensitive detection of acrolein in environmental water samples without derivatization using liquid chromatography tandem mass spectrometry
 
  • Details
Options

Fast and sensitive detection of acrolein in environmental water samples without derivatization using liquid chromatography tandem mass spectrometry

Date issued
2019
Author(s)
Chiriac, Florentina Laura  
National Research and Development Institute for Industrial Ecology, ECOIND  
Paun, Iuliana  
National Research and Development Institute for Industrial Ecology, ECOIND  
Galaon, Toma  
National Research and Development Institute for Industrial Ecology, ECOIND  
Pirvu, Florinela  
National Research and Development Institute for Industrial Ecology, ECOIND  
DOI
10.1007/s11356-019-06634-5
Abstract
A fast and sensitive SPE - LC - MS / MS method for the determination of acrolein in environmental water samples using activated charcoal as SPE adsorbent was developed. The novelty of this study consists in acrolein extraction, separation and detection without the need of a derivatization process. Physicochemical properties of acrolein, such as low molecular weight and high polarity represent real challenges for extraction, separation, and detection of this pollutant using SPE-LC-MS/MS. These were addressed by choosing a suitable chromatographic column which ensures a good peak symmetry and retention for the analyte, as well as the choice of SPE adsorbent suitable for retaining very polar compounds like acrolein from the aqueous matrix. The chromatographic column was a Synergi Fusion RP (150 × 2.0 mm, 4.0 μm) with a C18 stationary phase modified with polar embedded amide groups. Activated charcoal adsorbent used as SPE extraction media was able to extract efficiently highly polar molecules such as acrolein and 13C3-acrylamide (internal standard) from water samples. Using this method, the obtained extraction recovery for acrolein was 88% at a 50 ng/L concentration level. Overall method quantitation limit (LOQ) for acrolein in water was established at 3.8 ng/L. The newly developed SPE-LC-MS/MS method was successfully applied to detect acrolein occurrence in wastewater and drinking water samples. Acrolein level in these samples ranged from LOQ to 122 ng/L.
Subjects

Acrolein

SPE-LC-MS/MS

Polar-embedded column...

Activated charcoal

Wastewater

Drinking water

Files
No Thumbnail Available
Name

2019 Acroleina.pdf

Size

633.34 KB

Format

Adobe PDF

Checksum

(MD5):d804c51c15cecb9131c22e93471f185f

ECOIND logoECOIND logo
ECOLIB logoECOLIB logo
ROAR
ECOLIB logoECOLIB logo
Copyright 2025 ECOIND | End User Agreement | Send Feedback | Cookie settings | Privacy policy
DSpace Software Provided by PCG Academia