Repository logoRepository logoEcolib
Institutional
repository
  • Communities & Collections
  • Browse
AAA
  • Log In
    New user? Click here to register.Have you forgotten your password?
  1. Home
  2. ECOLOGY AND POLLUTION CONTROL
  3. Conference Papers
  4. New HPLC Method for Surfactants Detection in Wastewaters Samples
 
  • Details
Options

New HPLC Method for Surfactants Detection in Wastewaters Samples

Date issued
2022-05
Author(s)
Paun, Iuliana  
National Research and Development Institute for Industrial Ecology, ECOIND  
Chiriac, Florentina Laura  
National Research and Development Institute for Industrial Ecology, ECOIND  
Pirvu, Florinela  
National Research and Development Institute for Industrial Ecology, ECOIND  
Iancu, Vasile  
National Research and Development Institute for Industrial Ecology, ECOIND  
Covaliu, Cristina Ileana  
National Research and Development Institute for Industrial Ecology, ECOIND  
Abstract
Over the last decade, biocides have received increasing attention due to their widespread use, their transfer to aquatic ecosystems and their negative effect on aquatic organisms. Alkyl benzyl dimethyl ammonium chlorides are applied as bactericides and disinfectants in sanitary products and antistatic agents in the formula of laundry conditioners. The aim of this study was to provide a sensitive and robust HPLC-DAD method for detection of three biocides (dodecyl- (C12-), tetradecyl-(C14-), and hexadecyl- (C16-) benzyl dimethylammonium chloride) in wastewater samples. The an alytes separation was achieved using an Acclaim Surfactant Plus (3 µm, 150 mm × 3 mm) chroma tographic column, maintained at 30 °C. The isocratic mode elution using a binary phase of ammonium acetate 0,2 M (A): acetonitrile (B) as mobile phase (50:50, v/v) at a flow rate of 0.5 ml/min, allowed a run time of only 5 minutes. The linearity, accuracy and intermediate precision were vali dated. The HPLC-DAD method provides good linearity, with correlation coefficients from 0.9992 to 0.9997 in the concentration range from 1 to 100 mg/L. Very good precision values were obtained, with RSD% ranged from 1.37–2.27% for intra-day measurements and between 6.14 and 6.65% for inter-day measurements. The target biocides were isolated from wastewater samples through Solid Phase Extraction (SPE) procedure, using polymeric Strata-X Cartridges and acetonitrile and acetic acid (90%/10%) as elution solvent mixture. Recoveries (up to 86%) made possible the quantification biocides at very low levels, the limits of quantification (LOQs) being in the range of 4.5 and 7.6 µg/L. The method was successfully applied to wastewater samples, obtaining concentration values varying from few µg/L to few mg/L.
Subjects

HPLC-DAD

Biocides

Solid phase extractio...

Wastewater samples

Files
Loading...
Thumbnail Image
Name

manuscript Iuliana.pdf

Description
Poster
Size

233.67 KB

Format

Adobe PDF

Checksum

(MD5):79b08ff7c053d577f4d7f4f7db2d6b72

ECOIND logoECOIND logo
ECOLIB logoECOLIB logo
ROAR
ECOLIB logoECOLIB logo
Copyright 2025 ECOIND | End User Agreement | Send Feedback | Cookie settings | Privacy policy
DSpace Software Provided by PCG Academia