  4. Simultaneous Determination of 17 Phenolic Compounds in Surface Water and Wastewater Matrices Using an HPLC-DAD Method
 
  • Details
Options

Simultaneous Determination of 17 Phenolic Compounds in Surface Water and Wastewater Matrices Using an HPLC-DAD Method

Journal
Environments
ISSN
2076-3298
Date issued
2024-06-01
Author(s)
Paun, Iuliana  
National Research and Development Institute for Industrial Ecology, ECOIND  
Pascu, Luoana Florentina  
National Research and Development Institute for Industrial Ecology, ECOIND  
Iancu, Vasile  
National Research and Development Institute for Industrial Ecology, ECOIND  
Chiriac, Florentina Laura  
National Research and Development Institute for Industrial Ecology, ECOIND  
Galaon, Toma  
National Research and Development Institute for Industrial Ecology, ECOIND  
Pirvu, Florinela  
National Research and Development Institute for Industrial Ecology, ECOIND  
DOI
10.3390/environments11060117
Abstract
<jats:p>A high-performance liquid chromatography with diode array detector (HPLC-DAD) analytical method was developed for the simultaneous detection of 17 phenolic compounds, including phenols, chlorophenols, alkylphenols, and nitrophenols, in two types of water matrices: wastewater and surface water. Prior to HPLC-DAD determination, a solid-phase extraction (SPE) procedure was optimized. The proposed method uses multiwavelength analysis, with the optimum detection wavelengths selected as 268 nm, 280 nm, 386 nm, 304 nm, and 316 nm. The highest resolution was achieved using a chromatographic column, Eclipse XDB-C18 (150 × 4.6 mm, 5 μm), which was kept at 20 °C. The mobile phase consisted of a gradient elution program, with mobile phase A being a 0.1% H3PO4 aqueous solution and mobile phase B being acetonitrile. The flow rate was set at 0.6 mL/min. The 17 target phenolic compounds were fully separated in less than 27 min. All compounds showed good linear regression, with correlation coefficients higher than 0.999. The method’s quantitation limits ranged from 4.38 to 89.7 ng/L for surface water and 7.83 to 167 ng/L for wastewater. The recovery rates were in the range of 86.2–95.1% for surface water and 79.1–86.3% for wastewater. The SPE-HPLC-DAD method was proven to be fast, sensitive, accurate, and reproducible. The developed method was successfully applied for the analysis of the 17 phenolic compounds in real surface water and wastewater samples, with phenol, 2,4-DNP, and 2,4-DNP being determined at levels greater than the method’s limits of quantitation (LOQs). The proposed analytical method represents an original technical resource for the simultaneous determination of 17 phenolic compounds in environmental water matrices.</jats:p>
Files
Loading...
Thumbnail Image
Name

environments-11-00117 (1).pdf

Size

1.86 MB

Format

Adobe PDF

Checksum

(MD5):0f69eaf5f23852f5ef3a22c8dae30285

ECOIND logoECOIND logo
ECOLIB logoECOLIB logo
ROAR
ECOLIB logoECOLIB logo
Copyright 2025 ECOIND | End User Agreement | Send Feedback | Cookie settings | Privacy policy
DSpace Software Provided by PCG Academia